Product introduce

Transformers can transform the voltage of a network into the voltage matching the system or load and fulfill power transferring and distributing. Replace the transformer with a silicon steel core. AMDT can be widely applied in outdoor power distribution network systems, which is magnificently energy saving and can reduce air pollution. It is especially applicable for areas with insufficient power supply or fluctuating load and where daily maintain is hard. The hermetically sealed construction of AMDT prevents the oil and insulation material from being polluted, so the unit can serve in a humid environment. AMDT are the ideal equipment supplying power for distribution network in urban and rural areas.

Advantage of structure

The core is wound with amorphous alloy ribbons, which possesses a no-load loss 80% lower than S9 type transformer(with silicon steel core); The LV coils are wound with copper foil, which reinforces the ability to withstand short circuit for the transformer AMDT with connection Dyn11 can lighten harmonics impact on the network and improve the quality of the power supplied; The tank and cover are welded together, forming a hermetically sealed construction which lengthens the service life of AMDT and makes it repair-free; The vacuum oil filling eliminates all bubbles in the coils to ensure stable characteristics of insulation; Each transformer passes a full-wave lighting impulse test before delivery to ensure its safety operation. A peak voltage 25% higher than the value required by national standard is applied during the test.

SBH15-M Type 6~10kV

Single phase oil immersed amorphous alloy distribution transformer

The main technical parameters

Rated capacityKVA

Voltage Combination and  tap  range

connection of transformer winding

No-load loss

(W)

Load loss (W)

No-load current (%)

Short circuit impedance (%)

High voltage

(KV)

High voltage tap range

( %)

Low voltage

(KV)

5

10

16

20

30

40

50

63

80

100

125

 

 

 

 

6

6.3

10

10.5

11

 

 

 

 

 

 

±5%

 ±2x2.5%

 

 

 

  

 2  x0.22~0.24)

or

0.22~0.24

 

 

 

 

 

II0

II6

 

20

20

20

30

30

40

40

50

60

70

90

150

260

370

430

630

780

1100

1140

1400

1650

1950

2.4

2.2

2.0

1.8

1.6

1.4

1.2

1.0

0.9

0.8

0.7

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

Oil immersed amorphous alloy distribution transformer

The main technical parameters

Rated capacityKVA

Voltage Combination and  tap  range

connection of transformer winding

No-load loss

(W)

Load loss (W)

No-load current (%)

short  circuit impedance (%)

High voltage

(KV)

High voltage tap range

( %)

Low voltage

(KV)

30

50

63

80

100

125

160

200

250

315

400

500

630

800

1000

1250

1600

2000

2500

 

 

 

 


6

6.3

6.6

10

10.5

11

 

 

 

 

 

 



±5%

 ±2x2.5%

 

 

 

 

 




0.4

 

 

 

 

 



Dyn11

Yyn0

 

33

43

50

60

75

85

100

120

140

170

200

240

320

380

450

530

630

750

900

630/600

910/870

1090/1040

1310/1250

1580/1500

1890/1800

2310/2200

2730/2600

3200/3050

3830/3650

4520/4300

5410/5150

6200

7500

10300

12000

14500

17400

20200

1.70

1.30

1.20

1.10

1.00

0.90

0.70

0.70

0.70

0.50

0.50

0.50

0.30

0.30

0.20

0.20

0.20

0.20

0.20

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.5

4.5

4.5

4.5

4.5

5.0

5.0

SBH15-M Type 20kV

Oil-immersed amorphous alloy core power transformer

The main technical parameters

Rated capacityKVA

Voltage Combination and  tap  range

connection of transformer winding

No-load loss

(W)

Load loss (W)

No-load current (%)

Short circuit impedance (%)

High voltage

(KV)

High voltage tap range

( %)

Low voltage

(KV)

30

50

63

80

100

125

160

200

250

315

400

500

630

800

1000

1250

1600

2000

2500

 

 

 

 

 

 

 

 

24

22

20

 

 

 

 

 

 

 

 

 

±5%

±2x2.5%

 

 

 

 

 

 

 

 

 

0.4

 

 

 

 

 

 

 

 

Dyn11

Yyn0

 

    40

55

65

75

90

100

120

145

165

200

240

290

370

450

530

620

750

900

1080

690/660

1010/960

1200/1150

1440/1370

1730/1650

2080/1890

2540/2420

3000/2860

3520/3350

4210/4010

4970/4730

5940/5660

6820

8250

11330

13200

15950

19140

22220

1.50

1.20

1.10

1.00

0.90

0.80

0.60

0.60

0.60

0.50

0.50

0.50

0.30

0.30

0.30

0.20

0.20

0.20

0.20

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

6.0

6.0

6.0

6.0

6.0

6.0

6.0

 



Welcome to our website! Please send your words at any time in the following form and ask us, we will contact you and provide you with the corresponding service as soon as possible. Please write in English.

Amorphous alloy core transformers

Learn More

SBH15 Amorphous Alloy Core Transformer